FAQ'S
Frequently Asked Questions
What is backflow in plumbing?
Backflow is water moving the wrong direction through a pipe, from your property back toward the public main. When that reversed flow carries fertilizer, pool chemicals, or boiler water with it, the contamination can reach every tap connected to the same distribution system.
What causes backflow to occur?
Two conditions cause it. Backsiphonage happens when pressure in the public main drops, often during a main break, hydrant use, or firefighting, and pulls water backward. Backpressure happens when a pump, boiler, or elevated tank on your property pushes harder than the supply.
What's a cross-connection hazard in plumbing?
A cross-connection is the point where potable water touches a non-potable source, such as an irrigation line, a boiler feed, a chemical dispenser, or a private well. Each is rated low or high hazard, and that rating decides which assembly must protect it.
Is a backflow preventer required by code in California?
Yes. The State Water Resources Control Board's Cross-Connection Control Policy Handbook, in force since July 1, 2024, requires every public water system to run a containment program, and local purveyors decide which service connections must carry an approved assembly under it.
What are the backflow testing requirements in California?
Assemblies must be field-tested at least annually, immediately after installation, repair, relocation, or winterizing depressurization, and only by a certified tester using approved procedures. A failed assembly must be repaired or replaced within 30 days of the failure notice, then retested.
Who is qualified to perform a backflow test?
Only a tester certified by an organization the State Water Board recognizes, such as the California-Nevada AWWA, ABPA, or ASSE, may submit an official report. Holt Backflow Testing, LLC is on both purveyors' verified tester lists for Big Bear City, CA.
How do I know if I have a backflow preventer?
Look near your water meter, at the irrigation tie-in, or on the fire sprinkler riser for a brass body with two shutoff valves and small test cocks along its length. Newer services almost always carry one, and irrigation systems usually do.
What type of backflow device do I need?
The hazard decides. High-hazard connections such as wells, chemical feeds, and fire systems with antifreeze require a reduced pressure assembly, while low-hazard uses may be protected with a double check valve, and irrigation without backpressure can use a pressure vacuum breaker.
Why does a backflow preventer need to be installed in the front of my house?
Containment assemblies must sit as close as practical to the service connection, before the first branch line, and outside the public right of way. Placing the device near the meter means nothing can tie in ahead of it and bypass the protection.
Should a double check backflow preventer be installed above or below ground?
Above ground. California's current policy sets the lowest point of a newly installed double check between 12 and 36 inches over finished grade, and a below-ground vault is allowed only when the water purveyor approves it because no other location works.
Why do I need a backflow preventer on my irrigation system?
Sprinkler heads sit in soil that holds fertilizer, animal waste, and pesticides. When main pressure drops, that water can siphon backward through the heads and into your house lines. Local purveyors list irrigation systems among the connections that require an assembly.
Do you need to cover backflow preventers in winter?
In this climate, yes. Big Bear Lake Department of Water and Power's installation standard calls for an enclosure insulated to R-38 and heat tape on all above-ground piping, because water trapped inside a check body expands as it freezes and splits the casting.
What is a freeze-proof backflow preventer?
No assembly is freeze-proof, since every approved model traps some water between its checks. The term usually refers to a unit paired with a heated enclosure or drained through a stop-and-waste valve before November 1, when Big Bear Lake requires irrigation shut off.
How can you tell if a backflow preventer is bad?
Watch for a steady discharge from the relief port, a sudden drop in pressure downstream, water that will not pass through, visible cracks or corrosion on the body, or a failed annual test reading. Any of those means the assembly needs attention.
How do you protect backflow devices from theft?
Brass assemblies are targeted for scrap value, especially units 2 inches and smaller sitting in the open. Locking steel cages, tamper-resistant enclosures, and valve-stem protectors on fire services deter most attempts, and the enclosure must still leave the test cocks and shutoffs reachable.
What do I do if my backflow prevention device is stolen?
Shut off at the stop-and-waste valve, never at the meter, and report the loss to your purveyor, because a missing assembly leaves the connection unprotected. Holt Backflow Testing, LLC installs replacements in Big Bear City, CA and files the new test.
Where do I get a backflow device?
Plumbing supply houses stock the common sizes, but the model must appear on the USC Foundation approved list, with matching shutoff valves, or the purveyor will not accept it. Buying through the installer avoids a unit that fails approval before it is tested.
What is the purpose of backflow testing?
Field testing proves each check and relief valve is holding the pressure differential it was designed for. Because a worn disc or weak spring produces no symptom, the gauge reading is the only way to confirm the water behind it is protected.
Do commercial properties need different backflow services?
Usually. Retail, industrial, and municipal sites carry several assemblies across restrooms, kitchens, irrigation, fire lines, and process equipment, so testing is grouped into one visit with a summary report listing each device by location and result. High-hazard sites may face more frequent testing.